Bauteile
| Id | Kürzel | Dicke in m | Einsatzort | Bauweise | Export | |
|---|---|---|---|---|---|---|
| 65 | B_bBST80_bOSB15_bGF12 | 0.107 | Innenwand | brettstapel (BST) | XML | |
| 124 | B_bCB16 | 0.016 | Sonstiges | timber frame construction (TFC) | XML | |
| 125 | B_bCB16_iMW80_bCB16 | 0.112 | Innenwand | timber frame construction (TFC) | XML | |
| 92 | B_bCB19 | 0.019 | Sonstiges | timber frame construction (TFC) | XML | |
| 127 | B_bCB19_frT120||aO120 | 0.139 | Sonstiges | timber frame construction (TFC) | XML | |
| 86 | B_bCLT100 | 0.1 | Innenwand | cross laminated timber (CLT) | XML | |
| 129 | B_bCLT100 | 0.1 | Innenwand | cross laminated timber (CLT) | XML | |
| 63 | B_bCLT105 | 0.105 | Innenwand | cross laminated timber (CLT) | XML | |
| 88 | B_bCLT135 | 0.135 | Innenwand | cross laminated timber (CLT) | XML | |
| 76 | B_bCLT140 | 0.14 | Innenwand | cross laminated timber (CLT) | XML | |
| 72 | B_bCLT160 | 0.16 | Trenndecke | cross laminated timber (CLT) | XML | |
| 97 | B_bCLT160 | 0.16 | Trenndecke | cross laminated timber (CLT) | XML | |
| 42 | B_bCLT162 | 0.162 | Trenndecke | cross laminated timber (CLT) | XML | |
| 87 | B_bCLT200 | 0.2 | Trenndecke | cross laminated timber (CLT) | XML | |
| 83 | B_bCLT80 | 0.08 | Innenwand | cross laminated timber (CLT) | XML | |
| 105 | B_bCLT80 | 0.08 | Innenwand | cross laminated timber (CLT) | XML | |
| 101 | B_bCLT80_aO50_bCLT80 | 0.21 | Innenwand | cross laminated timber (CLT) | XML | |
| 56 | B_bCLT81 | 0.081 | Innenwand | cross laminated timber (CLT) | XML | |
| 253 | B_bCO100 | 0.1 | Sonstiges | reinforced concrete (RCO) | XML | |
| 254 | B_bCO100 | 0.1 | Sonstiges | reinforced concrete (RCO) | XML | |
| 255 | B_bCO100 | 0.1 | Sonstiges | reinforced concrete (RCO) | XML | |
| 132 | B_bCO160 | 0.16 | Trenndecke | reinforced concrete (RCO) | XML | |
| 130 | B_bGF10_frT120||aO120 | 0.13 | Sonstiges | timber frame construction (TFC) | XML | |
| 126 | B_bGF12_frT120||aO120 | 0.1325 | Sonstiges | timber frame construction (TFC) | XML | |
| 131 | B_bGF12_frT120||iMW100_aO105_frT120||iMW100_bGF12 | 0.37 | Gebäudetrennwand | timber frame construction (TFC) | XML | |
| 77 | B_bGF18_bGF18_bCLT140_bGF18_bGF18 | 0.212 | Innenwand | cross laminated timber (CLT) | XML | |
| 75 | B_bGF18_bGF18_bCLT80_bGF18_bGF18 | 0.152 | Innenwand | cross laminated timber (CLT) | XML | |
| 91 | B_bGP10 | 0.01 | Sonstiges | timber frame construction (TFC) | XML | |
| 74 | B_bGP12_bCLT80_bGP12 | 0.105 | Innenwand | cross laminated timber (CLT) | XML | |
| 89 | B_bPW16 | 0.016 | Sonstiges | cross laminated timber (CLT) | XML | |
| 78 | B_jHB200 | 0.2 | Trenndecke | hollow box grid (HB) | XML | |
| 21 | B_sCE120_ipMF7_wC45_jHB200||wL100 | 0.32 | Trenndecke | hollow box grid (HB) | XML | |
| 73 | B_sCE50_ipMF7_bCLT160 | 0.25 | Trenndecke | cross laminated timber (CLT) | XML | |
| 40 | B_sCE50_ipMF7_bWF6_jHB169||wL78 | 0.26 | Trenndecke | hollow box grid (HB) | XML | |
| 25 | B_sCE50_ipMF7_wC58_bBST120 | 0.232 | Trenndecke | brettstapel (BST) | XML | |
| 81 | B_sCE50_ipMF7_wL94_bCLT160 | 0.31 | Trenndecke | cross laminated timber (CLT) | XML | |
| 79 | B_sCE50_ipMF7_wL94_jHB200 | 0.35 | Trenndecke | hollow box grid (HB) | XML | |
| 106 | B_sCE80_ipMF7_bCLT160 | 0.28 | Trenndecke | cross laminated timber (CLT) | XML | |
| 24 | B_sDRY25_ipRW40_fC90_bCLT135 | 0.24 | Trenndecke | cross laminated timber (CLT) | XML | |
| 98 | B_wL94_jHB200 | 0.26 | Trenndecke | hollow box grid (HB) | XML |